{"id":19983,"date":"2021-03-21T16:37:25","date_gmt":"2021-03-21T16:37:25","guid":{"rendered":"https:\/\/goldstonehvacr.com\/?post_type=product&#038;p=19983"},"modified":"2021-07-28T14:36:27","modified_gmt":"2021-07-28T14:36:27","slug":"flow-restrictors","status":"publish","type":"product","link":"https:\/\/goldstonehvacr.com\/fr\/produit\/flow-restrictors\/","title":{"rendered":"Limiteurs de d\u00e9bit"},"content":{"rendered":"<p><strong>1. COLLECTEURS (COLLECTEURS DE LIGNES DE LIQUIDE\/COLLECTEURS DE LIGNES D&#039;ASPIRATION) :<\/strong><\/p>\n<ul>\n<li>Les collecteurs GSI peuvent contribuer \u00e0 optimiser l&#039;efficacit\u00e9 de votre serpentin, r\u00e9duisant ainsi la taille du serpentin et de l&#039;unit\u00e9 globale.<\/li>\n<li>Des limiteurs de d\u00e9bit diff\u00e9rents peuvent \u00eatre install\u00e9s dans chaque branche pour \u00e9quilibrer les serpentins.<\/li>\n<li>Les collecteurs seront test\u00e9s pour v\u00e9rifier le d\u00e9bit et l&#039;\u00e9tanch\u00e9it\u00e9 afin de garantir la qualit\u00e9 et le dimensionnement ad\u00e9quat des restricteurs dans chaque branche.<\/li>\n<li>Toutes les connexions cuivre-cuivre facilitent le brasage.<\/li>\n<li>Les anneaux de brasage peuvent \u00e9galement \u00eatre pr\u00e9install\u00e9s.<\/li>\n<\/ul>\n<p><strong>2. Limiteur de d\u00e9bit bidirectionnel amovible\u00a0:<\/strong><\/p>\n<ul>\n<li>Remplacer un tube capillaire est rentable.<\/li>\n<li>Conception monobloc, facile \u00e0 manipuler et \u00e0 installer.<\/li>\n<li>Flux bidirectionnel avec combinaison de filtre.<\/li>\n<li>Polyvalence en termes de longueur, de configuration des extr\u00e9mit\u00e9s, de taille de l&#039;orifice et de configuration de courbure du tube en cuivre.<\/li>\n<li>Gamme compl\u00e8te de tailles d&#039;orifices, et facile \u00e0 changer sur le chantier.<\/li>\n<li>Configurations d&#039;extr\u00e9mit\u00e9 personnalis\u00e9es.<\/li>\n<li>Gamme compl\u00e8te de tailles d&#039;orifices.<\/li>\n<\/ul>\n<p><strong>3. Limiteur de d\u00e9bit bidirectionnel<\/strong><strong>:<\/strong><\/p>\n<ul>\n<li>Remplacer un tube capillaire est rentable.<\/li>\n<li>Conception monobloc, facile \u00e0 manipuler et \u00e0 installer.<\/li>\n<li>Flux bidirectionnel avec combinaison de filtre.<\/li>\n<li>Gamme compl\u00e8te de tailles d&#039;orifices.<\/li>\n<li>Raccordements 3\/8\u2033 et 1\/2\u2033.<\/li>\n<\/ul>\n<p><strong>4. Distributeur agr\u00e9\u00e9 Flo :<\/strong><\/p>\n<ul>\n<li>Rentable.<\/li>\n<li>Gamme compl\u00e8te de circuits, toutes tailles et quantit\u00e9s confondues.<\/li>\n<li>Limiteur facilement rempla\u00e7able sur site, sans brasage requis.<\/li>\n<li>Gamme compl\u00e8te de mod\u00e8les d&#039;entr\u00e9e d&#039;eau.<\/li>\n<li>Un design personnalis\u00e9 est disponible.<\/li>\n<\/ul>\n<p><strong>5. Limiteur de d\u00e9bit unidirectionnel d\u00e9tachable<\/strong><strong>:<\/strong><\/p>\n<ul>\n<li>Remplacer un tube capillaire est rentable.<\/li>\n<li>Conception monobloc, facile \u00e0 manipuler et \u00e0 installer.<\/li>\n<li>Polyvalence en termes de longueur, de configuration des extr\u00e9mit\u00e9s, de taille de l&#039;orifice et de courbure du tube en cuivre.<\/li>\n<li>configuration.<\/li>\n<li>Gamme compl\u00e8te de tailles d&#039;orifices, et facile \u00e0 changer sur le terrain.<\/li>\n<li>Configurations d&#039;extr\u00e9mit\u00e9 personnalis\u00e9es disponibles.<\/li>\n<li>Gamme compl\u00e8te de tailles d&#039;orifices.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>COLLECTEURS (COLLECTEURS DE CIRCULATION DE LIQUIDE\/COLLECTEURS DE CIRCULATION D&#039;ASPIRATION) Ces collecteurs sont utilis\u00e9s sur les serpentins en A, les serpentins plats, les unit\u00e9s de climatisation monoblocs, les serpentins de condenseur et les unit\u00e9s de pompe \u00e0 chaleur monoblocs. Con\u00e7us pour remplacer les tubes capillaires, difficiles \u00e0 manipuler et fragiles, ils permettent une perte de charge plus pr\u00e9visible. Ils remplacent les tubes capillaires et distribuent le fluide frigorig\u00e8ne diphasique vers un serpentin.<\/p>","protected":false},"featured_media":19991,"comment_status":"open","ping_status":"closed","template":"","meta":{"content-type":""},"product_brand":[],"product_cat":[233,144],"product_tag":[],"class_list":["post-19983","product","type-product","status-publish","has-post-thumbnail","product_cat-oem-promotion","product_cat-flow-distributors","first","instock","shipping-taxable","purchasable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Flow Restrictors - Gold Stone HVAC\/R<\/title>\n<meta name=\"description\" content=\"The manifolds are used on A-coils, slab coils, package air-conditioning units, condenser coils and package heat-pump units. Designed to replace capillary tubing which is hard to handle and easy damaged, giving a more predictable pressure drop. Replaces capillary tubes, distribute two-phase refrigerant to a coil.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/goldstonehvacr.com\/fr\/produit\/flow-restrictors\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flow Restrictors - Gold Stone HVAC\/R\" \/>\n<meta property=\"og:description\" content=\"The manifolds are used on A-coils, slab coils, package air-conditioning units, condenser coils and package heat-pump units. Designed to replace capillary tubing which is hard to handle and easy damaged, giving a more predictable pressure drop. Replaces capillary tubes, distribute two-phase refrigerant to a coil.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/goldstonehvacr.com\/fr\/produit\/flow-restrictors\/\" \/>\n<meta property=\"og:site_name\" content=\"Gold Stone HVAC\/R\" \/>\n<meta property=\"article:modified_time\" content=\"2021-07-28T14:36:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/08\/FLOW-RESTRICTORS.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flow Restrictors - Gold Stone HVAC\/R","description":"The manifolds are used on A-coils, slab coils, package air-conditioning units, condenser coils and package heat-pump units. Designed to replace capillary tubing which is hard to handle and easy damaged, giving a more predictable pressure drop. Replaces capillary tubes, distribute two-phase refrigerant to a coil.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/goldstonehvacr.com\/fr\/produit\/flow-restrictors\/","og_locale":"fr_FR","og_type":"article","og_title":"Flow Restrictors - Gold Stone HVAC\/R","og_description":"The manifolds are used on A-coils, slab coils, package air-conditioning units, condenser coils and package heat-pump units. Designed to replace capillary tubing which is hard to handle and easy damaged, giving a more predictable pressure drop. Replaces capillary tubes, distribute two-phase refrigerant to a coil.","og_url":"https:\/\/goldstonehvacr.com\/fr\/produit\/flow-restrictors\/","og_site_name":"Gold Stone HVAC\/R","article_modified_time":"2021-07-28T14:36:27+00:00","og_image":[{"width":500,"height":500,"url":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/08\/FLOW-RESTRICTORS.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/","url":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/","name":"Flow Restrictors - Gold Stone HVAC\/R","isPartOf":{"@id":"https:\/\/goldstonehvacr.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/#primaryimage"},"image":{"@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/#primaryimage"},"thumbnailUrl":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/08\/FLOW-RESTRICTORS.jpg","datePublished":"2021-03-21T16:37:25+00:00","dateModified":"2021-07-28T14:36:27+00:00","description":"The manifolds are used on A-coils, slab coils, package air-conditioning units, condenser coils and package heat-pump units. Designed to replace capillary tubing which is hard to handle and easy damaged, giving a more predictable pressure drop. Replaces capillary tubes, distribute two-phase refrigerant to a coil.","breadcrumb":{"@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/#primaryimage","url":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/08\/FLOW-RESTRICTORS.jpg","contentUrl":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/08\/FLOW-RESTRICTORS.jpg","width":500,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/goldstonehvacr.com\/product\/flow-restrictors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/goldstonehvacr.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/goldstonehvacr.com\/shop\/"},{"@type":"ListItem","position":3,"name":"Flow Restrictors"}]},{"@type":"WebSite","@id":"https:\/\/goldstonehvacr.com\/#website","url":"https:\/\/goldstonehvacr.com\/","name":"Gold Stone CVC\/R","description":"","publisher":{"@id":"https:\/\/goldstonehvacr.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/goldstonehvacr.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/goldstonehvacr.com\/#organization","name":"Goldstone CVC","url":"https:\/\/goldstonehvacr.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/goldstonehvacr.com\/#\/schema\/logo\/image\/","url":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/09\/gsi-logo.png","contentUrl":"https:\/\/goldstonehvacr.com\/wp-content\/uploads\/2019\/09\/gsi-logo.png","width":340,"height":159,"caption":"Goldstone HVAC"},"image":{"@id":"https:\/\/goldstonehvacr.com\/#\/schema\/logo\/image\/"}}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/product\/19983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/comments?post=19983"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/media\/19991"}],"wp:attachment":[{"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/media?parent=19983"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/product_brand?post=19983"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/product_cat?post=19983"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/goldstonehvacr.com\/fr\/wp-json\/wp\/v2\/product_tag?post=19983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}